hydrophilic foldable lens
To inquire, Select Product/s & Click on

Product Code : 12

[Select]
Product Specification

        FOLDABLE LENS:(ISO-CE0434)

    SHREEJI MICRO SYSTEMS INC

INJECTING PROCEDURE
1.Load the Pusher into the Injector piston from the Pusher Holder. 5.Hold the cartridge wings together tightly to keep the loaded cartridge closed.
2.Lubricate the inner surface of the Cartridge with a Viscoelastic. 6.Slide the cartridge into the opening of the Appa Injector till it sits properly in the slot.
3.Take the Lens from the glass bottle with forceps. 7.Advance the piston firmly in smooth motion till it enters into the Cartridge.
4.Push the Lens down with the forceps between the bends of the wings and parallelly close the wings. 8.Insert the tip of the Cartridge through the incision.
Note:
1.The lens should be injected within a minute or two after loading the lens because viscoelastic may lose its lubricity when exposed into air for long period.

2.When loading the lens into the cartridge,make sure that thehaptics are not caught between the wings when they are closed.

Implantation Data
Folding & Unfolding Good to Excellent
Memory Excellent
Biocompatibility Excellent
Average visual acuity Good to Excellent with no inflammation present
Dislocation No cases reported
Opacification No cases reported
Incidende of PCO Very Low
YAG laser compatibility Excellent (where needed)
The Specification of the HEMA Material
Nature Copolymer of hydroxy ethyl Methacrylate and Methyl methacrylate
UV Blocker AEHB
Linear Expansion 1.127 ± 0.01 at 20oC
Radial Expansion 1.122 ± 0.01 at 20oC
Water content 26% at 20oC
Refractive index 1.460 HYDRATED at 20oC
Refractive index 1.461 HYDRATED at 35oC
Optical transmission  95%
Density 1.18g/cm3 HYDRATED
Tensile Strength 56.86 kg/cm2
Elongation to Break 279%
Sterilization Moist Heat Sterilization
Diopter Range 8.00 D - 30.0 D in 0.5 Diopter Increment
 
 
 
 

Other Products
exporter of intra ocular lens
exporter of intra ocular lens
micro surgical blades
micro surgical blades
Orthopaedic Bipolar
Orthopaedic Bipolar
capsuler tension ring
capsuler tension ring
Opthalmic Surgical Instruments
Opthalmic Surgical Instruments
MVR Blades
MVR Blades
 
<< Back
 
 
Contact Details
SHREEJI MICRO SYSTEMS INC.
230, Karma Estate, nr. trikampura patia, Phase-3, GIDC, Vatva,Ahmedabad - 382445, Gujarat, India
Phone:91-79-25831733
Fax:91-79-25893476
Send Mail  
Key Personnel
Mr. Anil K. Chauhan (CEO)
Mobile:+919824600855


Copyright © 2006 tradeindia.com. All Rights Reserved. Designed & Developed by